The hexapod units for the MIFO beamline of the PTB at BESSY feature the lastest updates of the hexapod design for compact size, straightforward alignment, and calibration at reliably excellent performance.
The constant-strut-length hexapod design used in this switching mirror unit is adapted from that of the EMIL beamlines hexapods (see projects P405 to P412).
This soft X-ray deflecting mirror unit is part of the SIX beamline, dedicated to high resolution soft X-ray scattering experiments. Energy resolution and pointing stability are here of crucial importance. It features an adapted constant-strut-length mechanism accounting for space constraints due to the proximity to the experimental station of the resonant innelastic X-ray scattering spectrometer (RIXS).
The constant-strut-length hexapod design used in this soft X-ray deflecting mirror unit is adapted from that of the EMIL beamlines hexapods (see projects P405 to P412).
This hard X-ray switching mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror switching is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
The constant-strut-length hexapod design used in this soft X-ray deflecting mirror unit is adapted from that of the EMIL beamlines hexapods (see projects P405 to P412). This mirror unit is part of the SIX beamline, dedicated to high resolution soft X-ray scattering experiments. Energy resolution and pointing stability are here of crucial importance.
This hard X-ray split mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror splitting is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
This soft X-ray deflection mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The vacuum chamber accomodates not only the actual beam but also the passing soft and hard X-ray beams of the neighbouring branches.
This soft X-ray split mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The mirror splitting is realized by a vertical movement. The vacuum chamber accomodates not only the actual beam but also the passing…
This hard X-ray deflection mirror unit is part of the combined hard and soft X-ray EMIL beamlines at BESSY. It features an optimized design of the constant-strut-length hexapod mechanism used for the first Bestec hexapod (see project P377). The vacuum chamber accomodates not only the actual beam but also the passing soft X-ray beam of the neighbouring branch.